MS-57SH

Pyrheliometer

ISO 9060:2018 Class A + Integrated window Heating
Ultra-fast and accurate, the MS-57SH is a unique digital DNI sensor fully traceable to the World Radiometric Reference with competition-beating long-term stability and exceptional reliability. Adds integrated solid-state window heating to the already industry-leading features and characteristics of the ‘fast-response’ and ‘spectrally flat’ ISO 9060:2018 Class A.

MS-57SH

Ultra-fast and incredibly accurate, with competition-beating long-term stability and exceptional reliability; the ISO 9060:2018 Class A MS-57SH Pyrheliometer is a unique, second-to-none, direct normal incidence (DNI) solar irradiance sensor fully traceable to the World Radiometric Reference.

Designed for solar energy research, monitoring, and meteorological applications and built to weather extreme conditions, the MS-57SH features an operating temperature range from -40 to +80°C and comes with an integrated low power heater to prevent dew and frost deposition on the outside window.

Made in Japan, our design and commitment to quality ensure that the MS-57SH is best in class, and for every application. The MS-57SH built on that achievement with the addition of Modbus 485 RTU and SDI-12 digital outputs for improved compatibility with data logger systems; also introducing new internal diagnostic sensors, now standard to all S-Series sensors, offering visibility over internal temperature, humidity, tilt angle; helping to ensure optimum performance without the need for regular physical checks.

These features, along with EKO’s unique 5-year recalibration interval, and new low power consumption integrated solid-state window heater make the MS-57SH the best value Class A sensors available; ideal for complex networks, hard to reach locations, and monitoring networks with restricted access.

 

Key Features:

 

  • ISO 9060:2018 Class A, Spectrally Flat & Fast Response
  • Smart 2-channel Digital Interface (Modbus RTU | SDI-12)
  • <1.4W Integrated High-Efficiency window Heating for dew & frost resistance
  • <0.2s Ultra-fast response for always accurate measurements
  • Unique <0.5% non-stability change of 5-years
  • Level A EMI/EMC Electronics Surge Filter & Protection
  • Internal Diagnostics for tilt angle, temperature and relative humidity
  • 5 Years Warranty & Recommended Recalibration Interval
  • ISO 17025 accredited calibration

Accessories

Compare

ISO 9060:2018

Response time 95%

< 0.2 Sec

Zero offset A – Thermal Radiation (200W/m²)

Zero offset B – Temperature change (5K/hr)

Zero offset C – Total zero off-set

Non-stability (change/year)

Non-linearity (at 1000W/m²)

± 0.2%

Spectral Error

Temperature Response (-30°C to 60°C)

± 0.5%

Temperature Response (-40°C to 70°C)

± 1%

Tilt Response (0-90° | 1000W/m²)

Wavelength Range

200 to 4000 nm (50% points)

Irradiance range (W/m²)

Operating temperature

Signal Output

Sensor Diagnostic

Additional Signal Processing Error

< 1W/m²

Ingress protection

IP67

Supply voltage range

8 to 30 VDC

Power Consumption

Standard Cable Length