MS-80SH

Pyranometer

Class A + Integrated Dome Heating + Spectrally Flat & Fast Response
With integrated high-efficiency dome heating, the MS-80SH is the new standout choice for value, accuracy, speed, reliability and IEC 61724-1:2021 Class A monitoring.

MS-80SH

The MS-80 set new industry standards on launch in 2016 and remains a class-leader for ISO 9060:2018 Class A solar sensors today, one of the few Class A pyranometers before the MS-80S and MS-80SH, in the top tier ‘fast-response’ and ‘spectrally flat’ sub-categories, with unprecedented low-zero-offset behaviour, and a 5-year recalibration interval.

The MS-80S built on that achievement with the addition of Modbus 485 RTU and SDI-12 digital outputs for improved compatibility with data loggers and SCADA systems; also introducing new internal diagnostic systems, now standard to all S-Series sensors, offering visibility over internal temperature, humidity, tilt, and roll angle; helping to ensure optimum performance without the need for regular physical checks.

These features, along with EKO’s unique 5-year recalibration interval, and new low power consumption integrated solid-state dome heater make the MS-80SH one of the best value Class A sensors available; ideal for complex networks, hard to reach locations, and monitoring networks with restricted access.

 

Key Features:

 

  • <1.4W Integrated High-Efficiency Dome Heating for dew & frost resistance
  • ISO 9060:2018 Class A, Spectrally Flat & Fast Response
  • <0.5s Super-Fast response for always accurate measurements
  • <1W/m² Record Lowest Zero Offset A, and <0.5% Lowest Non-Stability over 5-Years
  • Level A EMI/EMC Electronics Surge Filter & Protection
  • Internal Diagnostics for temperature, tilt, roll, and relative humidity
  • 5 Year Warranty & Recommended Recalibration Interval
  • ISO 17025 accredited calibration

Compare

ISO 9060:2018

Response time 95%

< 0.5 Sec

Zero offset A – Thermal Radiation (200W/m²)

Zero offset B – Temperature change (5K/hr)

Zero offset C – Total zero off-set

Non-stability (change/year)

Non-linearity (100 to 1000W/m²)

Directional Response (at 1000W/m² | 0 to 80°)

Spectral Error

Temperature response (-20°C to 50°C)

Tilt Response (0-90° | 1000W/m²)

Additional Signal Processing Error

< 1 W/m²

Technical Features :
Wavelength Range

285 to 3000 nm

Irradiance range (W/m²)

Signal Output

Sensor Diagnostic

Operating temperature

Supply voltage

Power Consumption

Ingress protection

IP67

Calibration traceability / uncertainty

Standard Cable Length

arrow-bottom-icon
icon-done
Added to list
There are no items on the list.
Chat with
EKO-Bot
Powered by ChatGPT
EKO-Bot
April 27, 2025 Hi, I am EKO-Bot, how can I assist you today?
Talk to support