Menu
Menu
The MS-80SH Plus+ is a trackerless solar monitoring station. Built around the unique internal rotating shadow band design of the MS-80SH Class A pyranometer. The MS-80SH Plus + adds the industry and ISO 9060:2018 class-leading MS-80SH Class A Pyranometer with integrated dome heating, and an original C-Box smart interface, for complete GHI, DHI, and calculated DNI measurements.
A practical solution to the increasing diversity of solar power plant locations and Photovoltaic (PV) applications, the MS-80SH Plus + can easily be deployed. This solution can provide a major benefit in terms of compliance with the updated IEC 61724-1 guidelines, as carrying out both GHI and DHI measurements is a criteria to fulfill the standard best practices when monitoring bifacial photovoltaic modules.
Key Features:
ISO 9060:2018 | |
---|---|
Output | Modbus 485 RTU, 4-20 mA, or 0-1 V (100 Ω) |
Logging values | Irradiance: GHI, DHI, DNI Meta data: T, RH, Tilt, Time, Long, Lat, solar elevation & azimuth |
Operating temperature range | -20 to 70 °C |
Wavelength Range | 285 – 3000 nm |
Power supply | 12 to 24 VDC |
Power Consumption | |
Weight | 4.5 kg |
Ingress protection | IP65 |
Standard Cable Length | 10m (Optional lengths 20m, 30m, 50m) |
Measurement interval | 15s (RSB mode) / 1s (TSB) |
Component specification | MS-80SH Pyranometer |
Tracking modes | RSB / TSB |
RSB Control Interval | 15s (Interval) |
Operating temperature range | -20 to 70 °C |
Power supply | 12 to 24 VDC |
Power consumption | <5 W (3.5W RSB mode) |
Weight | 3.5 kg |
Standard Cable length | 10m (Optional lengths 20m, 30m, 50m) |
Based on a revolutionary design, the MS-80SH Pyranometer is best-in-class for accuracy, speed, reliability and is one of the only top tier ‘fast-response’ and ‘spectrally flat’ Class A pyranometers with unprecedented low zero-offset behaviour available.
Featuring a state-of-the-art thermopile detector and Quartz diffusor technology, new internal diagnostics, a unique 4-channel interface, and Level A EMI/EMC electronic surge filter protection, the MS-80SH is IEC 61724-1 compliant and the standout choice for every application.
ISO 9060:2018 | Class A |
Response time 95% | < 0.5 Sec |
Zero offset A – Thermal Radiation (200W/m²) | ± 1W/m² |
Zero offset B – Temperature change (5K/hr) | ± 1W/m² |
Zero offset C – Total zero off-set | ± 2W/m² |
Non-stability (change/year) | < 0.5% / 5 years |
Non-linearity (100 to 1000W/m²) | ± 0.2% |
Directional Response (at 1000W/m² | 0 to 80°) | ± 10W/m² |
Spectral Error | ± 0.2% |
Temperature Response (-20°C to 50°C) | ± 0.5% |
Tilt Response (0-90° | 1000W/m²) | ± 0.2% |
Additional Signal Processing Error | < 1W/m² |
Technical Features : | |
Wavelength Range (nm) | 285 to 3000 |
Irradiance range (W/m²) | 0 to 4000 |
Signal Output | Modbus 485 RTU / SDI-12 4-20mA / 0-10mA / 0-1V |
Sensor Diagnostic | Relative Humidity ± 2% Temp. ± 0.1% / Tilt Angle ± 1° |
Operating temperature | -40 to 80°C |
Supply voltage | 8 to 30 VDC |
Power Consumption | < 1.4W |
Ingress Protection | IP 67 |
Calibration traceability / uncertainty | ISO 17025 / WRR / < 0.7% (k = 1.96) |
Standard Cable Length | 10m (Optional lengths 20m, 30m, 50m) |
Sealed inside an IP65 all-weather case, with GPS receiver, and Modbus 485 RTU output, the C-Box Modbus processing interface enables a range of sensor control and data processing functions.
Working in tandem with the ISO 9060:2018 Class A leading MS-80SH pyranometer, the C-Box, is an essential component of the unique MS-80SH Plus+ trackerless solar monitoring solution, allowing the system to accurately measure DNI, GHI, and to calculate DHI from measurement data and the position of the sun.
Communication interface | RS-485 Modbus |
Position and time | Built in GPS |
Channels | 2 |
Functions | RSB control, DNI, GHI, DHI processing |
Ingress protection IP | 65 |
Operating temperature range | -40 to 80°C |
Voltage range | 12 – 24 VDC |
Power consumption | <1 W |