The compact, industrial-grade ML-02 silicon pyranometer is made for high-quality irradiance measurements. ISO 9060:2018 Class C, fast response, light but tough, the ML-02 features a mono-silicon detector with a UV-resistant cone-shaped diffuser that helps to minimise soiling and water deposition, delivering an excellent cosine response, even at low solar elevation angles.
Made in Japan and manufactured to EKO's strict quality standards, the ML-02 comes with a 2-year warranty, 2-year recommended recalibration interval, and unique calibration, compliant with international standards, for a cost-effective alternative to larger thermopile-based sensors.
Primarily designed for meteorological, agricultural and environmental applications, the small size, high accuracy, quality construction and various mounting accessories available for the ML-02 have seen them mounted on drones, built into the bodies of solar-powered vehicles, fixed to building exteriors and more.
The ML-02 can also be combined with a POA bracket, M-box (Modbus®) and PT-100 temperature sensor to build a cost-effective PV rooftop monitoring system.
Specifications
Attribute | ML-02 | View Product | |
---|---|---|---|
ISO 9060:2018 | Class C | ||
Response time 95% | < 1 msec | ||
Zero offset A - Thermal Radiation (200W/m²) | 0 W/m² | ||
Zero offset B - Temperature change (5K/hr) | 0 W/m² | ||
Zero offset C - Total zero off-set | 0 W/m² | ||
Non-stability (change/year) | ± 2 % | ||
Non-linearity (100 to 1000W/m²) | < 0.2 % | ||
Directional Response (at 1000W/m² | 0 to 80°) | < 10 W/m² | ||
Spectral Error | ± 3.07 % | ||
Temperature Response (-20°C to 50°C) | < 0.15 % | ||
Tilt Response (0-90° | 1000W/m²) | 0 % | ||
Additional Signal Processing Error | - | ||
Sensitivity Approx. | 50 µV/W/m² | ||
Impedance | 50 Ω | ||
Technical Features | |||
Wavelength Range (nm) | 400 to 1100 | ||
Irradiance range (W/m²) | 0 to 2000 | ||
Signal Output | Analog (mV) | ||
Sensor Diagnostic | N/A | ||
Operating temperature | -30 to 80°C | ||
Supply voltage | N/A | ||
Power Consumption | N/A | ||
Ingress Protection | Equivalent to IP67 (IEC60529, JIS C0920) | ||
Calibration traceability / uncertainty | N/A | ||
Standard Cable Length | 5 m | ||
Leveling Plate | N/A |