MS-60S Albedometer
- ISO 9060:2018 Class B
- Spectrally Flat
Overview
Built with the same industry-leading features as the Class A MS-80S, the MS-60S comes with EKO’s unique 4-channel smart interface for compatibility with 99% of data loggers, DAQ, and SCADA systems.
The MS-60S, as part of the S-Series family of sensors, also includes internal diagnostic sensors for remote visibility over internal temperature, humidity, tilt and roll angle; ensuring optimum performance with reduced maintenance costs.
Spectrally flat and with a new double-dome construction for lower offsets and cosine errors, the MS-60S also includes a 5-year warranty and advanced surge protection for a Class B sensor that combines the latest technology with the highest standards of quality, accuracy, and reliability.
The MS-60S Albedometer consists of two MS-60S Pyranometers and the MS-Albedo Kit with a glare screen to measure albedo and total reflectance across various applications, including solar power plants with bi-facial PV modules.
MS-60S Pyranometers are manufactured with strict quality controls and performance evaluation. EKO provides calibration compliant with the international standards defined by ISO/IEC17025/9847 with a 2-year recommended re-calibration interval.
Pyranometer Specifications
Attribute | MS-60S | View Product | |
---|---|---|---|
ISO 9060:2018 | Class B | ||
Response time 95% | <18 Sec | ||
Zero offset A - Thermal Radiation (200W/m²) | ± 5W/m² | ||
Zero offset B - Temperature Change (5K/hr) | ± 2W/m² | ||
Zero offset C - Complete Zero off-set | ± 7W/m² | ||
Non-stability (change/year) | < 1.5% | ||
Non-linearity (100 to 1000W/m²) | ± 1% | ||
Directional Response (at 1000W/m² | 0 to 80°) | ± 18W/m² | ||
Spectral Error | ± 0.2% (Spectral selectivity ± 3%) | ||
Temperature Response (-20°C to 50°C) | ± 2% | ||
Tilt Response (0-90° | 1000W/m²) | ± 1% | ||
Additional Signal Processing Error | < 1W/m² | ||
Technical Features | |||
Wavelength Range (nm) | 285 to 3000 | ||
Irradiance range (W/m²) | 0 to 2000 | ||
Signal Output | MODBUS 485 RTU, SDI-12, 4-20mA, configurable 0-10mA / 0-1V* | ||
Sensor Diagnostic | Relative Humidity ± 2% Temp. ± 0.1% / Tilt Angle ± 1° | ||
Operating temperature | -40 to 80°C | ||
Supply voltage | 5 to 30 VDC | ||
Power Consumption | < 0.2 W | ||
Ingress Protection | IP 67 | ||
Standard Cable Length | 10m (Optional lengths 20m, 30m, 50m) |
Downloads
Trouble with Hibi?
Please select Hibi v1.1.21.0 from Downloads for any MS-80S model with a Serial Number higher than S21024001.
For models with a lower number, please download Hibi v1.1.14.0 using the link below.
Frequently paired together
Add all to listUse Case
Accurate Solar Radiation Measurements
The accurate solar radiation measurements and the reliable driving require a little knowledge and attention: think about environmental influences (wind, rain/snow, soiling), re-calibration (bi-annual), without mentioning…
Read more regarding Accurate Solar Radiation Measurements