The QRU-100 is designed to make the thermal performance evaluation of buildings and components easy, efficient, and accurate.
A critical requirement for modern construction, renovation, quality assurance, and energy efficiency assessment, the QRU-100 thermal monitoring kit includes separate indoor and outdoor measuring units. Indoor heat flux monitoring, together with indoor and outdoor temperature sensors, allow the QRU-100 to measure both thermal transmittance and thermal resistance, the U and R-Value of a wall or similar structure based on the standard methods defined in ISO 9869, ASTM C1046 and ASTM C1155.
The QRU-100 is delivered in a weather-proof case. Each measuring unit has a long-life battery and ultra-high-resolution data-logger that can store up to 4 million data points, preconfigured and ready to use.
Key Features:
| Number of measurement points | 3 |
|---|---|
| Logger Operating temperature range | -40 to +90°C |
| Data storage | 4 Million Data points |
| Datalogger battery life | Interval: >1min : 4 years – 10s : 230 days |
| Battery type of the data logger | Lithium type SL-750/S |
| Interface | USB to PC |
| Software | InfraLog 5 |
| Measurement unit IP level | IP66, IP68 |
| Transport case IP level | IP67 |
| Weight (Measurement unit) | 0.335 kg |
| Weight (incl Transport case) | 2.5 kg |
| Dimensions (Measurement Unit) | 113 x 80 x 60 mm |
| Dimensions (Transport case) | 350 x 295 x 150 mm |
| Sensor specifications : | |
| Heat flux sensor type | EKO HF-01S |
| Heat flux sensor nominal sensitivity | Approx. 28 μV/W/m² |
| Heat flux range | ±1500 W/m² |
| Heat flux sensor temperature range | -30 to 120°C |
| Temperature Sensor type | PT-1000, 4-wire |
| Temperature sensor accuracy | 1/10 DIN class |
| Temperature Sensor Range | -60 to 180°C |
| Sensor Cable Length | 3 m |